Explore CGX Workflows
Traditional EEG Is Hard to Scale for Human Factors Research
One Session Shows a Snapshot. Repeated Measures Reveal Cognitive Patterns.
Because performance is not static, single-session EEG recordings often miss important trend data. CGX enables repeatable EEG recordings across sessions, tasks, and study phases, helping researchers observe variability, adaptation, and performance trends over time.
Common Challenges:
-
Gel-based setups slow down repeated measurements
-
Complex systems reduce throughput and participant comfort
-
Real-world and simulation studies need flexible deployment
-
Cognitive-state metrics often depend on task-specific validation
-
Closed black-box systems make it hard to inspect or defend results
-
Multimodal workflows require synchronization across EEG, gaze, events, behavior, and physiology
One Metric Does Not Tell the Whole Story - Cognitive states depend on task, context, signal quality, and validation.
Workload, attention, fatigue, and engagement are not universal outputs that can be reduced to a single score in every context. They depend on the task, population, environment, artifact profile, behavioral outcomes, and analysis method.
CGX helps researchers build workflows preserving the underlying EEG data, synchronize it with task context, and support transparent validation instead of forcing every study into a closed metric.
The CGX Approach
CGX focuses on the EEG layer researchers need to trust.
Instead of forcing every neuroergonomics workflow into a closed analysis platform, CGX enables modular human factors research built around dry EEG, real-time acquisition, synchronized event markers, partner integrations, raw data export, and upcoming application-specific plug-ins.
The goal is practical deployment without giving up scientific control.
Why This Matters
-
Fast dry electrode setup
-
Wireless EEG for flexible study designs
-
Designed for repeated and applied measurements
-
Raw EEG access included and always free
-
Compatible with open research workflows
-
Supports multimodal integration with gaze, task events, and behavior
-
No black-box-only data model
-
Built for validation, inspection, and custom analysis
Transparent Cognitive-State Research
EEG can support research into cognitive workload, attention, fatigue, engagement, and passive BCI, but these signals need to be interpreted carefully. Metrics should be validated against the specific task, population, and environment being studied.
CGX workflows are designed to support that process. Researchers can inspect the signal, export raw EEG, compare pipelines, synchronize task events, and validate derived metrics against behavioral or physiological outcomes.
CGX Neuroergonomics Devices
Quick-20r v2
Dry EEG for Fast Human Factors Studies
Dry EEG system optimized for fast setup, repeatable measurements, and applied EEG workflows.
Highlights
-
Fast dry electrode setup
-
Standard 10-20 montage
-
Wireless acquisition
-
Strong fit for workload, attention, fatigue, and passive BCI studies


Quick-32r
Higher-Channel Dry EEG for Advanced Research
Dry EEG system for teams that need broader EEG coverage while preserving fast setup and flexible deployment.
Highlights
-
32-channel dry EEG
-
Broad spatial coverage
-
Useful for advanced cognitive-state workflows
-
Strong fit for simulation, BCI, and multimodal studies
Patch EEG
Low-Burden Frontal EEG for Targeted Workflows
Patch EEG is not a replacement for full-head EEG. Its value is simple deployment, low participant burden, and access to frontal EEG signals in workflows where a limited montage is scientifically appropriate.
Highlights
-
Minimal setup
-
Low participant burden
-
Useful for longitudinal and field-style protocols
-
Relevant for frontal workload, fatigue, sleep, and recovery-adjacent paradigms


AIM
Peripheral Physiology for EEG Experiments
Add synchronized physiological signals to EEG studies for richer context and multimodal analysis.
Highlights
-
Collect peripheral physiology alongside EEG
-
Supports signals such as ECG, EMG, PPG, GSR, Temp, and more
-
Synchronized data acquisition
-
Enhances multimodal research workflows
StimTrigger
Precise Event Synchronization for wireless EEG Experiments
Capture accurate stimulus timing and event markers to align EEG data with task events.
Highlights
-
Precise stimulus and event markers using proprietary 16-bit wireless marker technology
-
Reliable synchronization with EEG recordings
-
Supports experimental timing workflows
-
Recommended for applications requiring low-latency synchronization

CrunchBox Software
CGX Flowpoint
Central Hub for EEG Acquisition and Export
Flowpoint supports EEG acquisition, visualization, recording, export, and integration workflows.
Record data, inspect signal quality, stream through LSL, export EDF or CSV, and connect CGX EEG with third-party tools and custom analysis pipelines.
Outputs / Capabilities
-
Real-time EEG acquisition
-
Signal inspection
-
Raw EDF / CSV export
-
LSL streaming
-
Local workflow support


NeuroPype Signal Check
EEG Signal Quality Review
Signal quality workflows help researchers inspect whether EEG recordings are usable before moving into deeper analysis.
Outputs / Capabilities
-
Signal quality metrics
-
Channel-level review
-
Artifact context
-
Recording-level QC support
NeuroPype Band Power
Frequency-Domain EEG Analysis
Bandpower workflows support exploratory analysis of EEG frequency bands across conditions, sessions, or task states.
Outputs / Capabilities
-
EEG bandpower metrics
-
Condition comparisons
-
Exportable results
-
Research workflow support

Neuroergonomics Plug-ins
Application-Specific Workflows - in Development
CGX is developing application-specific plug-ins to support research workflows around cognitive state, workload, attention, fatigue, stress, and engagement.
Planned Workflow Areas
-
Cognitive-state research
-
Workload-related EEG features
-
Attention and sustained performance
-
Fatigue and vigilance research
-
Multimodal reporting where available
Partner Ecosystem
Human factors studies often combine brain activity with eye tracking, task behavior, physiological signals, event markers, simulation data, and subjective reports.
CGX supports a focused partner ecosystem for synchronized eye tracking, event markers, multimodal human behavior platforms, cognitive-state analytics, and open research tools.
Pupil Labs
Eye Tracking and EEG for Real-World Neuroergonomics
CGX is integrating with Pupil Labs eye tracking to support synchronized EEG and gaze workflows for neuroergonomics, human factors, UX research, training, mobility, and real-world attention studies.
Best For
-
EEG + eye tracking
-
Gaze and attention research
-
Cognitive workload studies
-
UX and interface testing
-
Mobility and real-world task studies
-
Passive BCI and adaptive systems




iMotions
Multimodal Human Behavior Research
iMotions supports multimodal human behavior research workflows that combine EEG with eye tracking, GSR/EDA, EMG, ECG, facial expression analysis, video, surveys, and behavioral data.
CGX adds value by providing fast dry EEG hardware, transparent raw data access, and flexible integration pathways for researchers who want EEG as part of a broader human behavior study.
Best For
-
UX and usability research
-
Human factors research
-
Training and performance
-
Consumer neuroscience
-
Multimodal behavior research
InnoBrain
Cognitive-State Analytics and Applied Mental-State Workflows
InnoBrain develops AI-enabled workflows for transforming EEG and behavioral data into cognitive-state and mental-state insights.
CGX can complement these workflows with dry EEG systems, deployment-friendly hardware, and transparent access to the raw signal layer.
Best For
-
Cognitive monitoring
-
Mental workload research
-
Readiness and performance workflows
-
Fatigue and safety indicators
-
Industrial and mobility applications
-
Applied human performance research


Cedrus
Precise Synchronization for EEG Experiments
Cedrus is a CGX partner for experiment synchronization and event-marker workflows. Together, CGX and Cedrus support precise timing for EEG studies that need to align brain data with task events, stimulus markers, and behavioral paradigms.
Best For
-
Event synchronization
-
Stimulus timing
-
Task-marker workflows
-
BCI experiments
-
Human factors studies
-
Multimodal EEG research
Neuroergonomics, Applied
Whether you are studying workload, attention, fatigue, engagement, or adaptive systems, CGX provides the EEG workflow from recording to analysis.
Cognitive Workload and Mental Effort
Measure Task Demand During Real-World and Simulated Performance
Study how task demands affect brain activity during decision-making, monitoring, training, multitasking, or interface use.
Used For
-
Cognitive workload studies
-
Mental workload monitoring
-
Simulation research
-
Human-machine interaction
-
Adaptive automation
-
Training evaluation

Why Researchers Choose CGX
-
Fast dry EEG setup
-
Raw EEG access for validation
-
Event synchronization support
-
Compatible with multimodal workflows
-
Flexible export for custom analysis
Attention, Engagement, and Gaze
Combine EEG and Eye Tracking for Attention Research
Use CGX EEG with eye tracking workflows to study attention, gaze behavior, engagement, and task performance.
Used For
-
UX research
-
Interface testing
-
Visual search
-
Training studies
-
Mobility research
-
Passive BCI workflows
Why Researchers Choose CGX
-
Pupil Labs integration
-
Dry EEG setup for repeated studies
-
EEG + gaze workflow potential
-
LSL and export-based workflows
-
Transparent access to underlying data

Fatigue and Vigilance
Study Alertness Across Repeated or Long-Duration Tasks
Use CGX EEG to study changes in vigilance, fatigue, drowsiness, or readiness during demanding or extended task conditions.
Used For
-
Transportation research
-
Shift work studies
-
Readiness research
-
Long-duration task monitoring
-
Training fatigue
-
Sleep and performance studies
Why Researchers Choose CGX
-
Practical repeated-measure workflows
-
Patch EEG option for low-burden protocols
-
Raw EEG access
-
Multimodal context through partner workflows
-
Useful for fatigue and recovery-adjacent research

Human Factors and Passive BCI
Build EEG Into Adaptive Research Workflows
Use EEG as one input into systems designed to adapt to workload, attention, fatigue, or performance context.
Used For
-
Passive BCI
-
Adaptive automation
-
Brain-computer interface research
-
Simulation studies
-
Human-machine teaming
-
Real-time research workflows
Why Developers Choose CGX
-
Wireless dry EEG systems
-
LSL streaming
-
Wireless event-marker support with StimTrigger
-
Open export
-
Partner Program path for validated methods and plug-ins

Neuroergonomics Bundles
Pre-configured EEG workflows for cognitive workload, attention, fatigue, multimodal human factors, and passive BCI research.
These bundles are suggested starting points. Final configurations should be matched to the study design.
Human Factors Starter
For pilot studies and early-stage cognitive workload research
What’s Included
-
1× Quick-20r v2
-
Flowpoint acquisition software
What You Get
-
Fast dry EEG setup
-
Raw EDF / CSV export
-
LSL streaming workflow
-
Signal quality workflow access
-
Flexible analysis path
Best For
-
Pilot studies
-
Cognitive workload research
-
Training studies
-
Early-stage feasibility work
Multimodal Performance
For EEG, eye tracking, event markers, and applied performance studies
What’s Included
-
1× Quick-20r v2
-
Flowpoint acquisition software
-
StimTrigger
-
AIM physiological sensor
-
Pupil Labs eye tracker
What You Get
-
Low latency synchronization of EEG with events and other modalities
-
EEG + gaze workflow
-
Human performance research setup
-
Full multimodal physiology
Best For
-
Eye tracking + EEG studies
-
Simulation studies
-
Attention and engagement research
-
Human-machine interaction
-
Multimodal setups
-
Passive BCI workflows
Advanced Neuroergonomics
For higher-channel EEG and advanced human factors programs
What’s Included
-
1× Quick-32r
-
Flowpoint acquisition software
-
StimTrigger
-
Signal quality and bandpower plug-ins
-
Partner integration consultation
-
Raw EDF / CSV export
-
LSL streaming workflow
What You Get
-
Higher-channel dry EEG workflow
-
More spatial coverage
-
Flexible multimodal integration
-
Research-ready export path
Best For
-
Advanced neuroergonomics labs
-
BCI and passive BCI research
-
Human factors programs
-
High-throughput applied EEG studies
Field / Longitudinal Add-On
For low-burden frontal EEG, fatigue, recovery, and sleep-adjacent protocols
What’s Included
-
Patch EEG
-
HydroFlex electrodes
-
Ring Oximeter
-
Flowpoint acquisition software
-
Sleep analysis plug-in(s)
What You Get
-
Raw EDF / CSV export
-
Low-burden frontal EEG recording
-
Repeated-measure workflow
-
Field-study flexibility
-
Sleep quality metrics in raltion to wake performanc
Best For
-
Feasibility studies
-
Unsupervised data collection
-
Longitudinal monitoring
-
Frontal EEG paradigms
-
Fatigue and recovery context
-
Sleep-adjacent human performance studies
Built Around Open EEG Workflows
All CGX neuroergonomics workflows are built around transparency, export, and integration.
All workflows include or support
-
Flowpoint acquisition platform
-
Raw EDF and CSV export
-
LSL streaming
-
Signal inspection
-
Event synchronization workflows
-
Compatibility with third-party analysis tools
-
Local-first data handling where applicable
-
Free access to raw EEG data
Frequently asked questions
Build a transparent EEG workflow for neuroergonomics and human factors research
Whether you are studying cognitive workload, attention, fatigue, engagement, training, simulation, passive BCI, or multimodal human behavior, CGX can help configure the right EEG hardware, software, integration pathway, and partner workflow.






DARPA
NASA
NIH
Office of Naval Research
Air Force Research Laboratory
Army Research Laboratory

